ISSN 2305-6894

Laboratory assessment of the efficiency of corrosion inhibitors at oilfield pipelines of the West Siberia region IV. Tests in a flow recirculation loop

  • , , and
1 OJSC Transenergostroi, Derbenevskaya nab. 7, bldg. 10, Moscow, 115114 Russian Federation
2 A. N. Frumkin Institute of Physical Chemistry and Electrochemistry, Russian Academy of Sciences, Leninskii pr. 31, Moscow, 119071 Russian Federation

Abstract: This article continues a series of publications dedicated to lab assessment of the efficiency of carbon dioxide corrosion inhibitors at oilfield pipelines of the West Siberia region. Results of the test in a flow recirculation loop are reviewed herein. The paper highlights the effect of temperature, test duration, oxygen concentration, condition of specimen surface, flow velocity, presence of hydrocarbon phase and inhibitor concentration on the corrosion rate and protective properties of a wide range of commercial inhibitors. The paper gives recommendations on specific conditions for testing inhibitors to assess their applicability for the protection of water lines, oil pipelines with low watercut and oil pipelines with high product watercut.

Keywords: corrosion inhibitors, test methods, oilfield pipelines

Int. J. Corros. Scale Inhib., , 2, no. 3, 203–215 PDF (595 K)
doi: 10.17675/2305-6894-2013-2-3-203-215

Download PDF (Total downloads: 513)

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Back to this issue content: 2013, Vol. 2, Issue 3 (pp. 162–254)